Battery safety charging cabinet SiS Li-Ion Basic Charge EI 90, with fire suppression system, HxW 1222 x 1148 mm, 2 power strips.
Battery safety charging cabinet SiS Li-Ion Basic Charge EI 90, with fire suppression system, HxW 1222 x 1148 mm, 2 power strips.
Prices exclude VAT. VAT will be calculated at checkout.
Regular price
€6,000.00
Regular price
Sale price
€6,000.00
Shipping calculated at checkout.
Estimated delivery: 39 days
Battery safety charging cabinet SiS Li-Ion Basic Charge EI 90, with fire suppression system, HxW 1222 x 1148 mm, 2 power strips
- Supplied = assembled
- Fittings = 2x10 fold trailing socket
- Height = 1222 mm
- Transfer height = 1600 mm
- Width = 1148 mm
- Depth = 591 mm
- Mains voltage = 230 V
- Internal height = 904 mm
- Internal width = 1004 mm
- Internal depth = 440 mm
- Fire resistance = 90 minutes
- Internal fittings = with fire suppression system
- Material = gypsum fibreboards, sheet steel
- Number of shelves = 2 pcs
- Body colour = brushed aluminium
- Door colour = traffic yellow RAL 1023
- Lock type = security, dual bit lock with 2 keys
- Door type = hinged door
- For media = lithium-ion batteries/rechargeable batteries
- Product type = battery charging safety cabinets
- Customs tariff number = 94038900
- Country of origin = DEU
- Gross weight = 397.3 kg
- Weight = 370 kg
- Safe charging and storage of multiple lithium-ion batteries in the cabinet
- Fire-resistant for up to 90 min. from inside and outside (EI 90), type-approved in accordance with DIN EN 1363-1:2012-10
- Maximum battery output per cabinet 3.5 kWh
- Integrated ventilation system with smoke detector and control unit with fire detection
- All-round fire protection seals that automatically foam up in the event of a fire
- Smooth-running hinged doors, opening angle 180°, not self-closing
- Fire-resistant cable inlets at the top and bottom
- Plinth with forklift access, height 100 mm with removable plinth cover
- The LaCont LI-ION Basic Charge EI 90 battery cabinet is the ideal entry-level model for the active and passive storage of lithium-ion batteries, with a main focus on fire protection
- The robust overall construction, tested by the Materials Testing Institute (MPA) Dresden, has a fire resistance of 90 minutes from the inside and outside (EI90) in accordance with DIN EN 1363-1
- Thanks to all-round fire protection seals that automatically foam up in the event of a fire, the LaCont LI-ION Basic protects against fires inside the cabinet, whereby the escape of smoke and toxic fumes is minimised
- The aim here is to gain time for the evacuation of people in the vicinity and for the fire brigade to initiate firefighting measures
- Further standard equipment includes, among other things, an integrated ventilation system with a smoke detector and fan (to shut off the power supply), height-adjustable grid shelf levels with a load capacity of 75 kg each (with an evenly distributed load), a plinth that can be moved underneath with a cover panel for easy transport, as well as fire-resistant cable glands for customer-side installation of a fire detector or potential-free contact
- Construction made of non-combustible building material (class A2-s1, d0 according to DIN EN 13501-1) incl. coating (body aluminium-coloured / doors RAL 1023 - traffic yellow), sump tray made of zinc plated sheet steel, 17 litre sump capacity
- Control unit of the SiS Li-Ion Basic Charge EI 90: - Fault message via optical signal and shutdown of the ventilation system, as well as extinguishing generator with power-independent triggering in case of fire and impermissible temperature increase - Automatic shutdown of the fan integrated in the cabinet upon smoke detection - Optical status display informs about the current status of the cabinet (fire detection, ventilation unit, socket strips) - In the event of a fire, the ventilation unit is automatically shut down to reduce air circulation - The power supply can be manually interrupted in the event of a fire by pressing the mains switch on the control unit - No standard acoustic alarm in the event of a fire - subsequent installation of a fire detector or potential-free contact by the customer is possible, through fire-resistant cable glands present in the cabinet - Nominal voltage 230 volts, fuse protection 1-phase 16A How it works for the model with a fire suppression system (aerosol extinguishing generator), with power-independent triggering in case of fire or an impermissible temperature increase from 180 °C: The triggering of the solid material contained in the extinguishing generator creates an aerosol of solid and gaseous particles
- These spread throughout the entire cabinet in milliseconds, displacing oxygen, diluting flammable gases and starting the extinguishing process
- Thus, the aerosol intervenes in the chemical chain reaction of the fire process, among other things by displacing oxygen, and interrupts it
- If the fire suppression system is not triggered, the maintenance-free service life is 10 years
- NOTE: The safety cabinets must be serviced once a year
- LaCont recommends contacting your damage insurance company, the fire brigade or experts before putting a cabinet into operation
- A risk assessment and a comprehensive fire protection concept are mandatory!